Compare Vokera boilers including combi, regular and system boilers and gas, oil and electric boilers.
For competitive prices, click on the button below to get boiler quotes for a new boiler installation.
Boiler | Efficiency | Output | Warranty | MPN | Boiler Type |
---|---|---|---|---|---|
Vokera Easi-Heat Plus 24S 24kW Gas System Boiler | 93% | 24kW | 5 Years | System | |
Vokera Easi-Heat Plus 30S 30kW Gas System Boiler | 93% | 30kW | 5 Years | System | |
Vokera Evolve 18S 18kW Gas System Boiler | 94% | 18kW | 7 years | System | |
Vokera Evolve 24S 24kW Gas System Boiler | 94% | 24kW | 7 years | System | |
Vokera Evolve 30S 30kW Gas System Boiler | 94% | 30kW | 7 years | System | |
Vokera Evolve 35S 35kW Gas System Boiler | 94% | 35kW | 7 years | System | |
Vokera Mynute 35HE 35kW Gas System Boiler | 88.8% | 35kW | 2 years | System | |
Vokera Mynute i20 20kW Gas System Boiler | 89.5% | 20kW | 5 Years | System | |
Vokera Mynute i30 30kW Gas System Boiler | 89.1% | 30kW | 5 Years | System | |
Vokera Verve i50 50kW Gas System Boiler | 90% | 50kW | 2 years | 20117565 | System |
Vokera Vision 20s 20kW Gas System Boiler | 89% | 20kW | 5-7 Years | System | |
Vokera Vision 25s 25kW Gas System Boiler | 89.1% | 25kW | 5-7 Years | System |
Boiler | Efficiency | Output | Warranty | MPN | Boiler Type |
---|---|---|---|---|---|
Vokera Mynute 15VHE 15kW Open Vent Gas Regular Boiler | 89.3% | 15kW | 2 years | Regular | |
Vokera Mynute 20VHE 20kW Open Vent Gas Regular Boiler | 88.8% | 20kW | 2 years | Regular |
Fault Code | Fault Image | System Behaviour |
---|---|---|
_St | N/A | Autostop |
_CL | N/A | Call for service |
A01 | Ignition failure flame not sensed – internal fault | |
A02 | Limit thermostat fault | |
A03 | Fan fault | |
A04 | Insufficient system water pressure | |
A06 | Domestic how water (DHW) thermistor fault | |
A07 | Primary flow thermistor fault – temperature of water is too high. | |
A08 | Return thermistor fault – water temperature too high. | |
A09 | Flue thermistor or flue thermistor counter fault. | |
A11 | False flame | |
A77 | Low temperature thermostat fault | |
ADJ | N/A | Calibration |
ACO | Service operation | |
N/A | Flame on |
Fault Code | System Behaviour |
---|---|
P | Preheating function active |
P Blinking | Preheating function running |
Hours | Stand-by |
— | Off |
01 | Failure to ignite |
02 | Overheat |
03 | Problem with fan/flue |
04 | Insufficient water pressure |
05 | Reset as described for code 01 |
06 | Hot water thermistor open circuit |
07 | Primary thermistor open circuit |
Fault Code | System Behaviour |
---|---|
AL10, AL20, AL21, AL26, AL28, AL34 | Try resetting the boiler, if the fault reoccurs you need to contact a heating engineer. |
AL40 | Check the system’s pressure and refill if necessary. Reset the boiler, if the fault reoccurs then you need to contact a heating engineer. |
AL41 | Check system pressure – refill if necessary. If fault reoccurs, contact a heating engineer. |
AL52, AL55, AL60, AL71,AL73, AL74, AL79 | Contact a heating engineer. |
AL74, AL79 | Reset the boiler. If the fault reoccurs, contact a heating engineer. |
Fault Code | System Behaviour |
---|---|
E10 | Flame lockout |
E011 | Extraneous flame |
E020 | Limit thermostat |
E030 | Fan fault |
E040 | Water transducer – check system water pressure |
E041 | Water transducer – check system water pressure |
E042 | Water transducer fault |
E060 | Domestic hot water probe fault |
4070 | Fault flow sensor over temperature – flow sensor flow/return line probe differential alarm |
E077 | Main zone water thermostat |
E080 | Error with return line probe – over temperature outlet or differential alarm |
E090 | Flue gases over temperature probe |
E091 | Clean primary heat exchanger |
— | Water pressure low |
— | Water pressure high |
— | Boiler board communication lost |
— | BUS 485 communication lost |
E021, E022, E023, E024, E067. E088, E097 | Iono alarm |
E085, E094, E095 | Combustion fault/high CO |
E058 | Main voltage error |
E065 | Current modulation alarm |
E086 | Obstruction fumes alarm |