Compare Viessmann boilers including combi, regular and system boilers and gas, oil and electric boilers.
For competitive prices, click on the button below to get boiler quotes for a new boiler installation.
Boiler | Efficiency | Output | Warranty | MPN | Boiler Type |
---|---|---|---|---|---|
Viessmann WB1B Vitodens 100-W 13kW Gas Regular Boiler | 89.00% | 13kW | 5 years | Regular | |
Viessmann WB1B Vitodens 100-W 16kW Gas Regular Boiler | 89.1% | 16kW | 5 Years | Regular | |
Viessmann WB1B Vitodens 100-W 19kW Gas Regular Boiler | 89% | 19kW | 5 Years | Regular | |
Viessmann WB1B Vitodens 100-W 26kW Gas Regular Boiler | 89.3% | 26kW | 5 Years | Regular | |
Viessmann WB1B Vitodens 100-W 35kW Gas Regular Boiler | 88.7% | 35kW | 5 years | Regular |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
02 | Burner control switches to lockout | Safety chain was activated |
04, 05, 06, 08 | Burner control switches to lockout | Fan speed too high/low at start |
07, 09 | Burner control switches to lockout | Basic level of air pressure threshold in standby mode not correct |
0A | Burner control switches to lockout | Fault, fan speed |
0D | Burner control switches to lockout | Reset button pressed repeatedly or while burner is running |
1A, 1B | Burner blocked | Flow sensor 1, 2 faulty |
1F | Burner blocked | Differential flow rate too large |
25 | Boiler operates with high boiler water temperature | Emissions test switch turned to “hand symbol” for 30 minutes already |
26 | Boiler operates with continuous relay test | Setting mode for maximum or minimum rated input active for 30 minutes already |
35 | Boiler does not activate | Reset button (pressed while burner is OFF) with emissions test switch turned to “hand symbol” |
A2 | N/A | KM-BUS fault to Vitocom |
A5 | N/A | Short circuit / open circuit |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitodens 200 | Burner control switches to lockout. Fan does not idle after auto reset (incorrect fan rpm). | Severe wind conditions in vent system |
Vitodens 100-W | Burner blocked | Insufficient water flow, incorrect flow direction, defective flow switch. |
Fault Code | System Behaviour | Cause of Problem | |
---|---|---|---|
Vitodens 100-W | Burner blocked | Insufficient power supply | |
Vitodens 200 | Burner control switches to lockout | Flame signal still present after switching off |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitodens 222-F | Control mode | Code “0F” is only displayed in the fault history |
Vitotronic 300 / Vitotronic 300-K, with Vitotronic 300 / Vitodens 200-W / Vitocontrol-S, with Vitotronic 100 | Control mode / Controlled operation | Boiler service required |
Vitotronic 200 / 300 | Normal operation | Boiler service required |
Vitocontrol-S, MW1 with Vitotronic 100 / Vitotronic 300-K, MW1S with Vitotronic 100 | Control mode | Maintenance – “0F” is only displayed in the fault history |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitodens 200-W / 222-F / Vitotronic 300 / 200/ 200-H / 050/200-H / 300-K / vitocontrol-S | Boiler operates based on outdoor temperature of 32°F / 0°C | Short circuit – outdoor temperature sensor |
Vitotronic 300-K, MW2S with Vitotronic 100 / Vitodens 100-W (combiPLUS) / 200-w / Vitocontrol-S, WB2B with Vitotronic 100 | Controls as if the outdoor temperature / Constant Mode | Outdoor temperature sensor shorted out |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitodens 200-W / 222-F / Vitotronic 300 / 200/ 200-H / 050/200-H / 300-K / vitocontrol-S | Boiler operates based on outdoor temperature of 32°F | Short circuit – outdoor temperature sensor |
Vitotronic 300-K, MW2S with Vitotronic 100 / Vitodens 100-W (combiPLUS) / 200-w / Vitocontrol-S, WB2B with Vitotronic 100 | Control as if the outdoor temperature is in constant mode | Outdoor temperature sensor shorted out |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitodens 100 / 200-W / 222-F / Vitotronic 300-K With 100 / Vitocontrol-S | Boiler operates based on outdoor temperature of 32°F / 0°C / Constant Mode | Outdoor temperature sensor cable broken |
Vitotronic / 100 / 200 / 300 / 050/200-H /300-K / Vitocontrol-S, MW1 with Vitotronic 100 | Operates on basis of 32°F / 0°C outdoor temperature | Open circuit – Outdoor temperature sensor |
Vitotronic 200-H / Vitotronic 300-K, MW1B with Vitotronic 300 / Vitotronic 300-K, MW2B with Vitotronic 200 | Controls as if the outdoor temperature | Lead break – Outdoor temperature sensor |
Vitotronic 050/200-H | Activates after 0°C / 32°F outdoor temperature | Cable break – Outdoor temperature sensor |
Vitodens 100-W | Burner in fault mode | DIP switch S2 is set to “ON” |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitotronic 300 | Activates after 0°C / 32°F outdoor temperature | Communication fault, wireless outdoor temperature sensor |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitocontrol-S with Vitotronic 100 / Vitotronic 300 / 300-K / 200 / 100 | Stand-alone control unit without supply temperature sensor (possibly supply temperature not high enough) | Short circuit – Common supply temperature sensor |
Vitocontrol-S with Vitotronic 100 / Vitotronic 300-K, with Vitotronic 200 | Vitocontrol-S, controls in a stand-alone manner w/o supply temperature sensor (supply temperature may not be high enough) | Common supply temperature sensor shorted out |
Vitocrossal 300 | Regulates without supply temperature sensor (low-loss header) | Short circuit – System Flow temperature sensor |
Vitodens 200-W / 222-F | Regulates without supply temperature sensor (low-loss header) | Short circuit – System supply temperature sensor |
Vitotronic 050/200-H< / 200 / 200-H / 300 | Mixing valve closed | Short circuit – Supply temperature sensor / mixing valve circuit M1 |
Vitotronic 300-K, with Vitotronic 100 | Vitotronic 300-K, MW1S controls in a stand-alone manner w/o strap-on sensor (supply temperature may not be high enough) | Short circuit – Strap-on temperature sensor |
Vitodens 200-W | Regulates without supply temperature sensor (low-loss header) | System supply temperature sensor shorted out |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitotronic 200 / 300 | Operation without influence of return water temperature | Short circuit – Return water temperature sensor |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitocontrol-S with Vitotronic 100 | Vitocontrol-S, VD2/CT3/CM2 controls in a stand-alone manner w/o supply temperature sensor (supply temperature may not be high enough) | Open circuit – common supply temperature sensor |
Vitocontrol-S with Vitotronic 100 / Vitotronic 300-K,with Vitotronic 100 | Vitocontrol-S, WB2B controls in a stand-alone manner w/o supply temperature sensor (supply temperature might not be high enough) | Common supply temperature sensor cable broken |
Vitocrossal 300 / Vitodens 200-W / 22-F | Regulates without supply temperature sensor (low-loss header) | System supply temperature sensor cable broken |
Vitotronic 050/200-H | Mixing valve closes | Cable break – Supply temperature sensor |
Vitotronic 050/200-H | Mixing valve is closed | Open circuit – Supply temperature sensor of mixing valve circuit M1 |
Vitotronic 200-H / Vitotronic 200 / 300 | Mixing valve is being closed | Lead break – Supply temperature sensor in heating circuit with mixing valve M1 (heating circuit 1) |
Vitotronic 300 Vitotronic / 300-K with Vitotronic 300 / 200 | Stand-alone control unit without supply temperature sensor (possibly supply temperature not high enough) | Lead break, common supply temperature sensor |
Vitotronic 300-K with Vitotronic 100 | Vitotronic 300-K, MW1S controls in a stand-alone manner w/o strap-on sensor (supply temperature may not be high enough) | Open circuit – Strap-on temperature sensor |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitotronic 200 / 300 | Normal operation without influence of return water temperature | Open circuit 1 or 2 – Return water temperature sensor (of mixing valve circuit 1) |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitocontrol-S, with Vitotronic 100 / Vitocrossal 300 / Vitodens 200-W / 222-F / Vitotronic 100 / 200 / 300 | Adjustable high limit burner is started and stopped | Short circuit – Boiler water temperature sensor |
Vitocontrol-S with Vitotronic 100 / Vitodens 100-W (CombiPLUS)/ 200-1 | Burner blocked | Boiler water temperature sensor shorted out |
Fault Code | System Behaviour | Cause of Problem |
---|---|---|
Vitodens – 200-W / 222-F / COMBIPLUS | Burner blocked | Boiler water temperature sensor cable broken |
Vitotronic 100 / 200 / 300 / Vitocontrol-S with Vitotronic 100 | Burner is switched on and off by the adjustable high limit | Open circuit – Boiler temperature sensor |
Vitotronic 300-K with Vitotronic 300 / Vitotronic 300-K with Vitotronic 300 | The burner is started and stopped via a temperature controller | Lead break, boiler water temperature sensor |
Vitodens 100-W | Burner blocked | Boiler water temperature sensor lead broken |